MODEL 6201
PORTABLE APPLIANCE TESTER
INSTRUCTION MANUAL
KYORITSU ELECTRICAL INSTRUMENTS
WORKS,LTD.
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - MODEL 6201

MODEL 6201PORTABLE APPLIANCE TESTERINSTRUCTION MANUALKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.

Strona 2 - CONTENTS

3.5 Explanation for indications3.5.1 LCD DisplayNote) Over range display: "OL" is displayed on the LCD.3.5.2 LED for threshold value indicat

Strona 3 - 1. Safe testing

―9―● General specification, measuring range and accuracyVoltage(VOLT) measurement of main power supplyMeasurement of Protective conductor resistance(R

Strona 4

―10―Reference test conditionUnless otherwise specified, this specification is dependent on followingcondition.(1) Ambient temperature: 23±5℃(2) Relat

Strona 5

―11―5.1 Visual inspectionBefore starting a measurement, user should undertake visual checks on the mains cord, case and that the correct type and rate

Strona 6

WARNING● When the voltage of mains power supply is 265V or more, "HI-V" isdisplayed on the LCD and buzzer sounds (discontinuous sounds). In

Strona 7

―13―(3) Insert Test Lead with safety alligator clip(M-7129) in to the E terminal of theinstrument, and contact the tip of the Test Lead with the meta

Strona 8

―14―6. Measuring method6.1 Earthed appliance TestThe purpose of the test carried out for Class 1 appliances is to check theinsulation resistance betwe

Strona 9

―15―(3) Connect Test Lead M-7129 to Rpe terminal and clip the metal part of DUTwith alligator clip.(4) Press the START switch when above preparatio

Strona 10

―16―6.2 Double Insulation TestThe Class 2 appliances have the indication of "DOUBLE INSULATION" or the symbol of F. Double insulation test

Strona 11 - 4. Specification

―17―CAUTION● When the terminal is open or the resistance value exceeds measuringrange, "OL" mark (over range display) appears on the LCD.● D

Strona 12

1.Safe testing ...12. Procedure of removing cover ...

Strona 13

―18―(1) Plug the extension leads adaptor M-7140 to the IEC socket of M-6201 connector block.(2) Connect the plug of the adaptor M-7140 for extension l

Strona 14

―19―When the fuse blows during use, please replace with new one according tobelow procedure.(1) Use a flat head screwdriver and turn it about 45°to l

Strona 15

―20―8. ServicesIf this instrument should fail to operate correctly, return it to your distributor.Please remember to give all the information possible

Strona 16 - 6. Measuring method

―21―9. Case and strap assemblyStrap belt and probe case can be attached to the instrument as below.Pass the strap belt down through the side panel of

Strona 17 - Insulation

DISTRIBUTORKyoritsu reserves the rights to change specifications or designsdescribed in this manual without notice and without obligations.92-1559 03-

Strona 18

―1―1. Safe testing! Electricity is dangerous and can cause injury and death. Always treat it with thegreatest of respectand care. If you are not quite

Strona 19

―2―DANGER● This instrument can be connected only to the commercial power of240V+10%-10%, 50Hz.● For safety reasons, only use the Test Leads designed t

Strona 20 - Polarity

―3―2. Procedure of removing coverModel 6201 have a dedicated cover to protect against an impact from theoutside and prevent the operation part, the LC

Strona 21 - 7. Fuse replacement

―4―3.1 Product summaryThe Model 6201 is a hand-held portable appliance tester, performing fourfunctions to ensure the Safety of Class I and Class II a

Strona 22 - 8. Services

(1) Test socket (2) Terminal block(6)LCD (7) LED for test result (8)Start switch(9)Null/250V-500V   switch(10) Range switch(11) (3) (4) (5) Termi

Strona 23 - 9. Case and strap assembly

―6―(1)Test socketInsert the mains plug of DUT to this socket for the polarity test of protectiveconductor resistance, insulation resistance and Extens

Strona 24 - DISTRIBUTOR

(11)FuseProtected by a fuse of 600V/500mA ceramic fuse (F type Φ6.3x32mm).User can replace this fuse.(12)Mains cord(AU) M-7123This mains cord can be c